P5147503-1024x895 DynalalaP5147503-1024x895 Dynalala

DYNALAL III Low Air Mattress by Quart SKU#2540

 

Features

The DynaLAL III is ideal for individuals with Stage I – IV pressure wounds. Its high air flow allows for a maximum client weight of up to 1000 lbs.

This system provides two different methods of therapy, alternation (3:1 ratio) and pulsation. Both therapies allow for movement to assist with increasing blood flow to the area with skin breakdown.

Additional features include alarms for bottoming out, leaving bed and power outages.

Set up and maintenance are effortless, the control unit has 16 weight settings  to accommodate a wide range of individuals. Maintenance involves inspecting / cleaning the filter once a month.

Available in two sizes 36″ x 80″ and 48″ x 80″

Unique Features

  • “TRUE” LOW AIR LOSS TECHNOLOGY – Air escapes from 72 laser-cut openings and distributes equally under a vapour-permeable, quilted cover that acts to wick moisture away from the individual.
  • DEEP CELL ALTERNATION THERAPY – 15 independent 8″ inch high cells and 3 each 6″ cells in the foot section, gently inflate and deflate in a 3:1 cycle.
  • COMFORT LEVELS – 16 Comfort levels for different weight ranges
  • PULSATION MODE – Pressure in the cells will pulsate without complete offload.
  • ADJUSTABLE SECURITY TIES – Eight ties secure the system to any standard hospital bed frame.
  • BUILT-IN ALARM SYSTEM – Alarm sound will alert caregiver in the event of a power failure, sensor disconnect, bottoming out and falling out of bed.
  • FOWLER PRESSURE FUNCTION – This function adds extra air to support the hips and lower back when the head of the bed is raised above 30 degree angle.
Master Control Unit Features
  • STATIC MODE – For individuals unable to tolerate a moving surface, the “static” mode provides constant low-pressure for comfortable pressure relief.
  • ALTERNATION MODE – Cycle times can be set from 5-95 min. to best meet the treatment needs of each individual. Cells alternate in a 3:1 ratio so that the individual is always supported by 2/3 of the cells.
  • AUTO-FIRM MODE – This feature provides, within seconds, a stable surface for patient transfers and nursing procedures (returns to alternation mode after 30 min. if auto-firm is not deactivated).
  • SOFT/FIRM – 16 soft/firm settings are available for easy comfort adjustment. This allows the caregiver to fine tune therapeutic support and optimize comfort based on weight.
  • AUTO ALARM – This will alert the caregiver in the event of a power failure, leaving bed, sensor disconnect and bottoming-out.

Description

Features

The DynaLAL III is ideal for individuals with Stage I – IV pressure wounds. Its high air flow allows for a maximum client weight of up to 1000 lbs.

This system provides two different methods of therapy, alternation (3:1 ratio) and pulsation. Both therapies allow for movement to assist with increasing blood flow to the area with skin breakdown.

Additional features include alarms for bottoming out, leaving bed and power outages.

Set up and maintenance are effortless, the control unit has 16 weight settings  to accommodate a wide range of individuals. Maintenance involves inspecting / cleaning the filter once a month.

Available in two sizes 36″ x 80″ and 48″ x 80″

Unique Features

  • “TRUE” LOW AIR LOSS TECHNOLOGY – Air escapes from 72 laser-cut openings and distributes equally under a vapour-permeable, quilted cover that acts to wick moisture away from the individual.
  • DEEP CELL ALTERNATION THERAPY – 15 independent 8″ inch high cells and 3 each 6″ cells in the foot section, gently inflate and deflate in a 3:1 cycle.
  • COMFORT LEVELS – 16 Comfort levels for different weight ranges
  • PULSATION MODE – Pressure in the cells will pulsate without complete offload.
  • ADJUSTABLE SECURITY TIES – Eight ties secure the system to any standard hospital bed frame.
  • BUILT-IN ALARM SYSTEM – Alarm sound will alert caregiver in the event of a power failure, sensor disconnect, bottoming out and falling out of bed.
  • FOWLER PRESSURE FUNCTION – This function adds extra air to support the hips and lower back when the head of the bed is raised above 30 degree angle.
Master Control Unit Features
  • STATIC MODE – For individuals unable to tolerate a moving surface, the “static” mode provides constant low-pressure for comfortable pressure relief.
  • ALTERNATION MODE – Cycle times can be set from 5-95 min. to best meet the treatment needs of each individual. Cells alternate in a 3:1 ratio so that the individual is always supported by 2/3 of the cells.
  • AUTO-FIRM MODE – This feature provides, within seconds, a stable surface for patient transfers and nursing procedures (returns to alternation mode after 30 min. if auto-firm is not deactivated).
  • SOFT/FIRM – 16 soft/firm settings are available for easy comfort adjustment. This allows the caregiver to fine tune therapeutic support and optimize comfort based on weight.
  • AUTO ALARM – This will alert the caregiver in the event of a power failure, leaving bed, sensor disconnect and bottoming-out.